Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 155
Filtrar
1.
G Ital Cardiol (Rome) ; 25(5): 295-299, 2024 May.
Artigo em Italiano | MEDLINE | ID: mdl-38639118

RESUMO

Patent foramen ovale (PFO) is a remnant of normal fetal anatomy which may persist into adulthood, mostly asymptomatic. In some adults, PFO may result in a potential for shunting venous thromboembolism to the arterial circulation; less frequently it can cause interatrial, right-to-left shunting of deoxygenated blood. The pathogenesis of several medical conditions is related to the presence of PFO. Some randomized clinical trials have shown evidence of benefit for device closure as compared with medical therapy in patients with cryptogenic stroke. The literature reported several cases of carbon dioxide embolism during general laparoscopic surgery and sometimes stroke after laparoscopic or neurosurgery but there are neither prospective studies addressing these issues, nor randomized clinical trials assessing the effectiveness of pharmacotherapy or interventional procedures at decreasing risk. The European position paper suggests routine monitoring in non-cardiac surgery of patients with a PFO and no actual indications for closure. This article aims to further stratify the risk of periprocedural stroke and paradoxical embolism in this category of patients.


Assuntos
Embolia Paradoxal , Forame Oval Patente , Acidente Vascular Cerebral , Adulto , Humanos , Forame Oval Patente/complicações , Forame Oval Patente/cirurgia , Estudos Prospectivos , Acidente Vascular Cerebral/prevenção & controle , Acidente Vascular Cerebral/complicações , Prevenção Secundária/métodos , Embolia Paradoxal/etiologia , Embolia Paradoxal/prevenção & controle , Resultado do Tratamento
2.
EuroIntervention ; 20(5): e289-e300, 2024 Mar 04.
Artigo em Inglês | MEDLINE | ID: mdl-37982178

RESUMO

BACKGROUND: Microvascular resistance reserve (MRR) is a validated measure of coronary microvascular function independent of epicardial resistances. AIMS: We sought to assess whether MRR is associated with adverse cardiac remodelling, a low-flow phenotype and extravalvular cardiac damage (EVCD) in patients with severe aortic stenosis (AS) undergoing transcatheter aortic valve implantation (TAVI). METHODS: Invasive thermodilution-based assessment of the coronary microvascular function of the left anterior descending artery was performed in a prospective, multicentre cohort of patients undergoing TAVI. Coronary microvascular dysfunction (CMD) was defined as the lowest MRR tertile of the study cohort. Haemodynamic measurements were performed at baseline and then repeated immediately after TAVI. EVCD and markers of a low-flow phenotype were assessed with echocardiography. RESULTS: A total of 134 patients were included in this study. Patients with low MRR were more frequently females, had a lower estimated glomerular filtration rate and a higher rate of atrial fibrillation. MRR was significantly lower in patients with advanced EVCD (median 1.80 [1.26-3.30] vs 2.50 [1.87-3.41]; p=0.038) and in low-flow, low-gradient AS (LF LG-AS) (median 1.85 [1.20-3.04] vs 2.50 [1.87-3.40]; p=0.008). Overall, coronary microvascular function tended to improve after TAVI and, in particular, MRR increased significantly after TAVI in the subgroup with low MRR at baseline. However, MRR was significantly impaired in 38 (28.4%) patients immediately after TAVI. Advanced EVCD (adjusted odds ratio 3.08 [1.22-7.76]; p=0.017) and a low-flow phenotype (adjusted odds ratio 3.36 [1.08-10.47]; p=0.036) were significant predictors of CMD. CONCLUSIONS: In this observational, hypothesis-generating study, CMD was associated with extravalvular cardiac damage and a low-flow phenotype in patients with severe AS undergoing TAVI.


Assuntos
Estenose da Valva Aórtica , Isquemia Miocárdica , Substituição da Valva Aórtica Transcateter , Feminino , Humanos , Substituição da Valva Aórtica Transcateter/efeitos adversos , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/cirurgia , Estudos Prospectivos , Resultado do Tratamento
3.
Heart ; 110(4): 271-280, 2024 Jan 29.
Artigo em Inglês | MEDLINE | ID: mdl-37879880

RESUMO

OBJECTIVES: To ascertain whether invasive assessment of coronary physiology soon after recanalisation of the culprit artery by primary percutaneous coronary intervention is associated with the development of microvascular obstruction by cardiac magnetic resonance in patients with ST-segment elevation myocardial infarction (STEMI). METHODS: Between November 2020 and December 2021, 102 consecutive patients were prospectively enrolled in five tertiary centres in Italy. Coronary flow reserve (CFR) and index of microvascular resistance (IMR) were measured in the culprit vessel soon after successful primary percutaneous coronary intervention. Optimal cut-off points of IMR and CFR to predict the presence of microvascular obstruction were estimated, stratifying the population accordingly in four groups. A comparison with previously proposed stratification models was carried out. RESULTS: IMR>31 units and CFR≤1.25 yielded the best accuracy. Patients with IMR>31 and CFR≤1.25 exhibited higher microvascular obstruction prevalence (83% vs 38%, p<0.001) and lower left ventricular ejection fraction (45±9% vs 52±9%, p=0.043) compared with those with IMR≤31 and CFR>1.25, and lower left ventricular ejection fraction compared with patients with CFR≤1.25 and IMR≤31 (45±9% vs 54±7%, p=0.025). Infarct size and area at risk were larger in the former, compared with other groups. CONCLUSIONS: IMR and CFR are associated with the presence of microvascular obstruction in STEMI. Patients with an IMR>31 units and a CFR≤1.25 have higher prevalence of microvascular obstruction, lower left ventricular ejection fraction, larger infarct size and area at risk. TRIAL REGISTRATION NUMBER: NCT04677257.


Assuntos
Infarto do Miocárdio , Intervenção Coronária Percutânea , Infarto do Miocárdio com Supradesnível do Segmento ST , Humanos , Circulação Coronária , Imageamento por Ressonância Magnética , Microcirculação/fisiologia , Infarto do Miocárdio/complicações , Infarto do Miocárdio/diagnóstico , Volume Sistólico , Resultado do Tratamento , Resistência Vascular , Função Ventricular Esquerda/fisiologia , Estudos Prospectivos
4.
Artigo em Inglês | MEDLINE | ID: mdl-38160130

RESUMO

Valve-in-valve transcatheter aortic valve implantation (ViV TAVI) is rapidly arising as a safe and effective alternative to redo-surgery in the treatment of bioprostheses deterioration. While scientific community is currently focusing its attention on the most common limitations related to this procedure, such as the risk of coronary obstruction and patient-prosthesis mismatch, data regarding the first step of a ViV TAVI, the crossing of a degenerated bioprosthesis, are still lacking. The aim of this review is to analyze the available information about bioprosthesis crossing, to show the inherent challenges encountered by interventional cardiologists during valve crossing and to describe the current strategies to perform a correct crossing.

5.
JACC Cardiovasc Interv ; 16(21): 2615-2627, 2023 11 13.
Artigo em Inglês | MEDLINE | ID: mdl-37968032

RESUMO

BACKGROUND: Mitral valve-in-valve (ViV) is associated with suboptimal hemodynamics and rare left ventricular outflow tract (LVOT) obstruction. OBJECTIVES: This study aimed to determine whether device position and asymmetry are associated with these outcomes. METHODS: Patients undergoing SAPIEN 3 (Edwards Lifesciences) mitral ViV included in the VIVID (Valve-in-Valve International Data) Registry were studied. Clinical endpoints are reported according to Mitral Valve Academic Research Consortium definitions. Residual mitral valve stenosis was defined as mean gradient ≥5 mm Hg. Depth of implantation (percentage of transcatheter heart valve [THV] atrial to the bioprosthesis ring) and asymmetry (ratio of 2 measures of THV height) were evaluated. RESULTS: A total of 222 patients meeting the criteria for optimal core lab evaluation were studied (age 74 ± 11.6 years; 61.9% female; STS score = 8.3 ± 7.1). Mean asymmetry was 6.2% ± 4.4%. Mean depth of implantation was 19.0% ± 10.3% atrial. Residual stenosis was common (50%; mean gradient 5.0 ± 2.6 mm Hg). LVOT obstruction occurred in 7 cases (3.2%). Implantation depth was not a predictor of residual stenosis (OR: 1.19 [95% CI: 0.92-1.55]; P = 0.184), but more atrial implantation was protective against LVOT obstruction (0.7% vs 7.1%; P = 0.009; per 10% atrial, OR: 0.48 [95% CI: 0.24-0.98]; P = 0.044). Asymmetry was found to be an independent predictor of residual stenosis (per 10% increase, OR: 2.30 [95% CI: 1.10-4.82]; P = 0.027). CONCLUSIONS: Valve stenosis is common after mitral ViV. Asymmetry was associated with residual stenosis. Depth of implantation on its own was not associated with residual stenosis but was associated with LVOT obstruction. Technical considerations to reduce postdeployment THV asymmetry should be considered.


Assuntos
Fibrilação Atrial , Bioprótese , Implante de Prótese de Valva Cardíaca , Próteses Valvulares Cardíacas , Humanos , Feminino , Pessoa de Meia-Idade , Idoso , Idoso de 80 Anos ou mais , Masculino , Valva Mitral/diagnóstico por imagem , Valva Mitral/cirurgia , Implante de Prótese de Valva Cardíaca/efeitos adversos , Constrição Patológica/etiologia , Resultado do Tratamento , Cateterismo Cardíaco/efeitos adversos , Hemodinâmica , Sistema de Registros , Desenho de Prótese
6.
JACC Case Rep ; 22: 101978, 2023 Sep 20.
Artigo em Inglês | MEDLINE | ID: mdl-37790775

RESUMO

Ischemia with no obstructive coronary artery disease (INOCA) is not an uncommon diagnosis in patients presenting with chest pain who undergo clinically indicated coronary angiography. However, the symptoms reported by patients with INOCA may be heterogeneous, leading to misdiagnosis and undertreatment. Herein we report 3 clinical cases of INOCA misdiagnosis and describe how the cases were reinvestigated following the appropriate diagnostic pathway. (Level of Difficulty: Advanced.).

7.
Catheter Cardiovasc Interv ; 102(6): 1132-1139, 2023 11.
Artigo em Inglês | MEDLINE | ID: mdl-37668083

RESUMO

BACKGROUND: Limited data are available on transcatheter heart valves (THVs) durability in bicuspid aortic valve (BAV) stenosis. AIMS: To evaluate evaluating 4-year clinical and echocardiographic outcomes of patients with BAV undergoing transcatheter aortic valve implantation (TAVI). METHODS: The bicuSpid TAvi duraBILITY (STABILITY) registry is an Italian multicentre registry including all consecutive patients with BAV and severe aortic stenosis (AS), treated by means of TAVI between January 2011 and December 2017. Outcomes of interest were all-cause death at 4-year, over time changes in echocardiographic measurements, and THV durability according to the valve aortic research consortium (VARC)-3 update definitions. RESULTS: Study population included 109 patients (50% females; mean age 78 ± 7.5 years) with a mean Society of Thoracic Surgeons Predicted Risk of Mortality score of 5.1 ± 4.3%. Median follow-up (FU) duration was 4.1 years [interquartile range: 2.8-5.1]. The overall cumulative incidence of all-cause death by Kaplan-Meier estimates at 4 years was 32%. Compared to baseline, a significant decrease in transprosthetic mean gradient was obtained after TAVI (54 ± 16 vs. 10 ± 5 mmHg; p < 0.001), whereas a significant increase was observed at 4-year (13 ± 6.4 mmHg, p = 0.03). Cumulative incidence of hemodynamic valve dysfunction (HVD) was 4%. Six patients met HVD criteria: three moderate and three severe HVD. All three cases of severe HVD were clinically relevant (bioprosthetic valve failure [BVF]) with two patients receiving a reintervention (TAVI in TAVI), and one patient experiencing a valve-related death due to endocarditis. CONCLUSIONS: The STABILITY registry suggests that in patients with severe AS and BAV undergoing TAVI, postprocedural clinical benefits might last, over time, up to 4-year FU. The low rates of severe HVD and BVF may support the hypothesis of good THV durability also in BAV recipient.


Assuntos
Estenose da Valva Aórtica , Doença da Válvula Aórtica Bicúspide , Doenças das Valvas Cardíacas , Próteses Valvulares Cardíacas , Estenose da Valva Mitral , Substituição da Valva Aórtica Transcateter , Feminino , Humanos , Idoso , Idoso de 80 Anos ou mais , Masculino , Substituição da Valva Aórtica Transcateter/efeitos adversos , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/cirurgia , Constrição Patológica , Resultado do Tratamento , Doenças das Valvas Cardíacas/cirurgia , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/cirurgia , Sistema de Registros
8.
Minerva Cardiol Angiol ; 71(5): 504-514, 2023 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-37712217

RESUMO

#FullPhysiology is a comprehensive and systematic approach to evaluate patients with suspected coronary disease using PressureWire technology (Abbott Vascular, Santa Clara, CA, USA). This advancement in technology enables the investigation of each component of the coronary circulation, including epicardial, microvascular, and vasomotor function, without significantly increasing procedural time or technical complexity. By identifying the predominant physiopathology responsible for myocardial ischemia, #FullPhysiology enhances precision medicine by providing accurate diagnosis and facilitating tailored interventional or medical treatments. This overview aims to provide insights into modern coronary physiology and describe a systematic approach to assess epicardial flow-limiting disease, longitudinal physiological vessel analysis, microvascular and vasomotor dysfunction, as well as post- percutaneous coronary intervention (PCI) physiological results.


Assuntos
Doença da Artéria Coronariana , Isquemia Miocárdica , Intervenção Coronária Percutânea , Humanos , Doença da Artéria Coronariana/diagnóstico , Circulação Coronária , Medicina de Precisão
9.
MAbs ; 15(1): 2248671, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37610144

RESUMO

Identification of favorable biophysical properties for protein therapeutics as part of developability assessment is a crucial part of the preclinical development process. Successful prediction of such properties and bioassay results from calculated in silico features has potential to reduce the time and cost of delivering clinical-grade material to patients, but nevertheless has remained an ongoing challenge to the field. Here, we demonstrate an automated and flexible machine learning workflow designed to compare and identify the most powerful features from computationally derived physiochemical feature sets, generated from popular commercial software packages. We implement this workflow with medium-sized datasets of human and humanized IgG molecules to generate predictive regression models for two key developability endpoints, hydrophobicity and poly-specificity. The most important features discovered through the automated workflow corroborate several previous literature reports, and newly discovered features suggest directions for further research and potential model improvement.


Assuntos
Anticorpos Monoclonais , Imunoglobulina G , Humanos , Anticorpos Monoclonais/química , Aprendizado de Máquina
10.
Int J Cardiol ; 389: 131236, 2023 10 15.
Artigo em Inglês | MEDLINE | ID: mdl-37532153

RESUMO

BACKGROUND: Horizontal aorta (HA), defined by an aortic angulation (AA) ≥48°, is associated with worse outcomes particularly after self-expanding (SE) trans-catheter heart valve (THV) implantation. Although the SE ACURATE Neo THV demonstrated favorable procedural success rates in patients with HA, it remains associated with a non-negligible rate of moderate or greater paravalvular leak (PVL). OBJECTIVES: Aim of the study was to assess the performance of ACURATE Neo2 in the setting of HA. METHODS: We performed a multicenter cohort analysis on patients with severe aortic valve stenosis and HA undergoing transcatheter aortic valve replacement (TAVR) with the Neo or Neo2 THV enrolled in the ITAL-neo registry. The primary endpoint was a composite of early safety and clinical efficacy at 30 days according to the Valve Academic Research Consortium-3 (VARC-3). Secondary endpoints included the occurrence of moderate or severe PVL and 90-day clinical outcomes. RESULTS: Among 900 patients included in the ITAL-neo registry, 407 exhibited HA; of these, 300 received a Neo THV and 107 a Neo2 THV. HA, irrespective of the THV implanted, emerged as an independent risk factor for developing ≥ moderate PVL. Technical and device success at 30-day follow-up was comparable between groups. However, Neo2 was associated with a significantly lower rate of ≥moderate PVL vs. Neo: (5% vs. 15%; p < 0.001), which was confirmed also at 90-day follow-up. Additionally, no correlation was found between ≥moderate PVL and AA in the Neo2 group, while PVL degree increased proportionally to the AA in the Neo cohort. CONCLUSION: In patients with HA, the new generation Acurate Neo2 THV was associated with a comparable device success rate and a significantly lower rate of ≥moderate PVL, when compared with its predecessor.


Assuntos
Estenose da Valva Aórtica , Próteses Valvulares Cardíacas , Substituição da Valva Aórtica Transcateter , Humanos , Substituição da Valva Aórtica Transcateter/efeitos adversos , Desenho de Prótese , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/cirurgia , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/cirurgia , Resultado do Tratamento , Sistema de Registros
11.
EuroIntervention ; 19(7): 580-588, 2023 Sep 18.
Artigo em Inglês | MEDLINE | ID: mdl-37565470

RESUMO

BACKGROUND: Transcatheter aortic valve replacement (TAVR) in non-calcified aortic regurgitation (NCAR) is an off-label procedure. The balloon-expandable Myval includes extra-large sizes (30.5 mm and 32 mm) of interest in this setting. AIMS: We aimed to evaluate the safety and feasibility of Myval in NCAR. METHODS: This was an international, multicentre, observational study that enrolled all consecutive patients with symptomatic severe NCAR undergoing TAVR with the Myval device. The images were centrally analysed. RESULTS: A total of 113 patients were recruited, 64.6% were men, the mean age was 78.4±7.5 years, and the Society of Thoracic Surgeons score was 2.7±1.7%. Aortic root dilatation was present in 59.3% of patients, 7.1% were bicuspid, and the mean annular area was 638.6±106.0 mm2. The annular area was beyond the recommended range for extra-large sizes in 2.6% of cases, and additional volume was added in 92% (median 4 cc, up to 9 cc). The extra-large sizes were used in 95 patients (84.1%), and the mean oversizing was 17.9±11.0%. The technical success rate was 94.7%; the rate of residual ≥moderate aortic regurgitation was 8.9%, and the pacemaker rate was 22.2%. There were no cases of annular rupture, cardiac tamponade, or aortic dissection, but in 4 patients (3.5%) valve embolisation occurred (1 antegrade and 3 ventricular), all in cases with a tapered left ventricle outflow tract (p=0.007). Thirty-day and 1-year mortality were 5.3% and 9.7%, respectively. Technical success was associated with better survival (97.1% vs 72.7%; p=0.012), and valve embolisation was the main determinant of mortality (p=0.047). CONCLUSIONS: Myval is a feasible and safe option for selected non-operable patients with NCAR and demonstrated good midterm outcomes and lack of impact of oversizing on device durability.


Assuntos
Insuficiência da Valva Aórtica , Estenose da Valva Aórtica , Próteses Valvulares Cardíacas , Substituição da Valva Aórtica Transcateter , Masculino , Humanos , Idoso , Idoso de 80 Anos ou mais , Feminino , Substituição da Valva Aórtica Transcateter/métodos , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/cirurgia , Insuficiência da Valva Aórtica/diagnóstico por imagem , Insuficiência da Valva Aórtica/cirurgia , Estenose da Valva Aórtica/cirurgia , Resultado do Tratamento , Desenho de Prótese
13.
Int J Cardiol ; 384: 55-61, 2023 08 01.
Artigo em Inglês | MEDLINE | ID: mdl-37149007

RESUMO

BACKGROUND: In terms of pathophysiology, tricuspid regurgitation (TR), right ventricular function and pulmonary artery pressure are linked to each other. Our aim was to analyze whether the echocardiography-derived right ventricular free wall longitudinal strain/pulmonary artery systolic pressures (RVFWLS/PASP) ratio can improve risk stratification in patients with severe tricuspid regurgitation (TR). METHODS: In this single-center retrospective study, 250 consecutive patients with severe TR were enrolled from December 2015 to December 2018. Baseline clinical and echocardiographic parameters were collected. Echocardiography-derived TAPSE/PASP and RVFWLS/PASP were evaluated. The primary endpoint was all-cause mortality. RESULTS: Out of 250 consecutive patients, 171 meet inclusion criteria. Patients were predominantly female, with several cardiovascular risk factors and comorbidities. RVFWLS/PASP ≤0.34%/mmHg (AUC 0.68, p < 0.001, sensitivity 70%, specificity 67%) was associated with baseline clinical RV heart failure (p = 0.03). After univariate and multivariate analyses, RVFWLS/PASP, but not TAPSE/PASP, independently correlated with all-cause mortality (HR 0.004, p = 0.02). Patients with RVFWLS/PASP >0.26%/mmHg (AUC 0.74, p < 0.001, sensitivity 77%, specificity 52%) showed higher survival rates (p = 0.02). In addition at 24 months follow-up, the Kaplan-Meyer curves showed patients with RVFWLS >14% & RVFWLS/PASP >0.26%/mmHg had the best survival rate compared to patients without. CONCLUSION: RVFWLS/PASP is independently associated with baseline RV heart failure and poor long-term prognosis in patients with severe TR.


Assuntos
Insuficiência Cardíaca , Hipertensão Pulmonar , Insuficiência da Valva Tricúspide , Disfunção Ventricular Direita , Humanos , Feminino , Masculino , Prognóstico , Insuficiência da Valva Tricúspide/diagnóstico por imagem , Pressão Sanguínea , Ecocardiografia Doppler , Estudos Retrospectivos , Função Ventricular Direita/fisiologia , Artéria Pulmonar/diagnóstico por imagem
14.
Eur Heart J Cardiovasc Imaging ; 24(7): 887-896, 2023 06 21.
Artigo em Inglês | MEDLINE | ID: mdl-36916015

RESUMO

AIMS: Transcatheter aortic valve implantation (TAVI) is the treatment of choice for high-risk patients with severe aortic stenosis (AS). A portion of TAVI recipients has no long-term clinical benefit, and myocardial fibrosis may contribute to unfavourable outcomes. We aimed to assess the prognostic value of an interstitial fibrosis marker, extracellular volume fraction (ECV), measured at planning computed tomography (CT) before TAVI. METHODS AND RESULTS: From October 2020 to July 2021, 159 consecutive patients undergoing TAVI planning CT were prospectively enroled. ECV was calculated as the ratio of myocardium and blood pool differential attenuations before and 5 min after contrast administration, pondered for haematocrit. A composite endpoint including heart failure hospitalization (HFH) and death was collected by telehealth or in-person follow-up visits in the 113 patients constituting the final study population. Cox proportional hazards model was used to assess association between ECV and the composite endpoint.Median follow-up was 13 (11-15) months. The composite endpoint occurred in 23/113 (20%) patients. These patients had lower aortic valve mean pressure gradient [39 (29-48) vs. 46 (40-54) mmHg, P = 0.002] and left ventricular and right ventricular ejection fraction [51 (37-69) vs. 66 (54-74)%, P = 0.014; 45 (31-53) vs. 49 (44-55)%, P = 0.010] and higher ECV [31.5 (26.9-34.3) vs. 27.8 (25.3-30.2)%, P = 0.006]. At multivariable Cox analysis, ECV higher than 31.3% was associated to increased risk of death or HFH at follow-up (hazard ratio = 5.92, 95% confidence interval 2.37-14.75, P < 0.001). CONCLUSION: In this prospective observational cohort study, ECV measured at TAVI planning CT predicts the composite endpoint (HFH or death) in high-risk severe AS patients.


Assuntos
Estenose da Valva Aórtica , Substituição da Valva Aórtica Transcateter , Humanos , Substituição da Valva Aórtica Transcateter/efeitos adversos , Volume Sistólico , Resultado do Tratamento , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/cirurgia , Estudos Prospectivos , Função Ventricular Direita , Prognóstico , Valva Aórtica/cirurgia , Fibrose , Tomografia Computadorizada por Raios X , Tomografia , Função Ventricular Esquerda
15.
Front Med (Lausanne) ; 10: 1050531, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-36873865

RESUMO

Background: Microvascular lung vessels obstructive thromboinflammatory syndrome has been proposed as a possible mechanism of respiratory failure in COVID-19 patients. However, it has only been observed in post-mortem studies and has never been documented in vivo, probably because of a lack of CT scan sensitivity in small pulmonary arteries. The aim of the present study was to assess the safety, tolerability, and diagnostic value of optical coherence tomography (OCT) for the assessment of patients with COVID-19 pneumonia for pulmonary microvascular thromboinflammatory syndrome. Methods: The COVID-OCT trial was a multicenter, open-label, prospective, interventional clinical study. Two cohorts of patients were included in the study and underwent pulmonary OCT evaluation. Cohort A consisted of patients with COVID-19 with a negative CT scan for pulmonary thrombosis and elevated thromboinflammatory markers (D-dimer > 10,000 ng/mL or 5,000 < D-dimer < 10,000 ng/mL and one of: C-reactive Protein > 100 mg/dL, IL-6 > 6 pg/mL, or ferritin > 900 ng/L). Cohort B consisted of patients with COVID-19 and a CT scan positive for pulmonary thrombosis. The primary endpoints of the study were: (i) to evaluate the overall safety of OCT investigation in patients with COVID-19 pneumonia, and (ii) to report on the potential value of OCT as a novel diagnostic tool for the diagnosis of microvascular pulmonary thrombosis in COVID-19 patients. Results: A total of 13 patients were enrolled. The mean number of OCT runs performed in each patient was 6.1 ± 2.0, both in ground glass and healthy lung areas, achieving a good evaluation of the distal pulmonary arteries. Overall, OCT runs identified microvascular thrombosis in 8 patients (61.5%): 5 cases of red thrombus, 1 case of white thrombus, and 2 cases of mixed thrombus. In Cohort A, the minimal lumen area was 3.5 ± 4.6 mm2, with stenosis of 60.9 ± 35.9% of the area, and the mean length of thrombus-containing lesions was 5.4 ± 3.0 mm. In Cohort B, the percentage area obstruction was 92.6 ± 2.6, and the mean thrombus-containing lesion length was 14.1 ± 13.9 mm. No peri-procedural complications occurred in any of the 13 patients. Conclusion: OCT appears to be a safe and accurate method of evaluating the distal pulmonary arteries in hospitalized COVID-19 patients. Here, it enabled the first in vivo documentation of distal pulmonary arterial thrombosis in patients with elevated thromboinflammatory markers, even when their CT angiogram was negative for pulmonary thrombosis. Clinical trial registration: ClinicalTrial.gov, identifier NCT04410549.

16.
JACC Cardiovasc Interv ; 16(4): 415-425, 2023 02 27.
Artigo em Inglês | MEDLINE | ID: mdl-36858660

RESUMO

BACKGROUND: Transcatheter aortic valve replacement (TAVR)-related coronary artery obstruction prediction remains unsatisfactory despite high mortality and novel preventive therapies. OBJECTIVES: This study sought to develop a predictive model for TAVR-related coronary obstruction in native aortic stenosis. METHODS: Preprocedure computed tomography and fluoroscopy images of patients in whom TAVR caused coronary artery obstruction were collected. Central laboratories made measurements, which were compared with unobstructed patients from a single-center database. A multivariate model was developed and validated against a 1:1 propensity-matched subselection of the unobstructed cohort. RESULTS: Sixty patients with angiographically confirmed coronary obstruction and 1,381 without obstruction were included. In-hospital death was higher in the obstruction cohort (26.7% vs 0.7%; P < 0.001). Annular area and perimeter, coronary height, sinus width, and sinotubular junction height and width were all significantly smaller in the obstructed cohort. Obstruction was most common on the left side (78.3%) and at the level of the coronary artery ostium (92.1%). Coronary artery height and sinus width, but not annulus area, were significant risk factors for obstruction by logistic regression but performed poorly in predicting obstruction. The new multivariate model (coronary obstruction IF cusp height > coronary height, AND virtual valve-to-coronary distance ≤4 mm OR culprit leaflet calcium volume >600 mm3) performed well, with an area under the curve of 0.93 (sensitivity = 0.93, specificity = 0.84) for the left coronary artery and 0.94 (sensitivity = 0.92, specificity = 0.96) for the right. CONCLUSIONS: A novel computed tomography-based multivariate prediction model that can be implemented routinely in real-world practice predicted coronary artery obstruction from TAVR in native aortic stenosis.


Assuntos
Estenose da Valva Aórtica , Oclusão Coronária , Substituição da Valva Aórtica Transcateter , Humanos , Mortalidade Hospitalar , Resultado do Tratamento , Coração
17.
JACC Cardiovasc Interv ; 16(4): 396-411, 2023 02 27.
Artigo em Inglês | MEDLINE | ID: mdl-36858659

RESUMO

BACKGROUND: The optimal access route in patients with severe peripheral artery disease (PAD) undergoing transcatheter aortic valve replacement (TAVR) remains undetermined. OBJECTIVES: This study sought to compare clinical outcomes with transfemoral access (TFA), transthoracic access (TTA), and nonthoracic transalternative access (TAA) in TAVR patients with severe PAD. METHODS: Patients with PAD and hostile femoral access (TFA impossible, or possible only after percutaneous treatment) undergoing TAVR at 28 international centers were included in this registry. The primary endpoint was the propensity-adjusted risk of 30-day major adverse events (MAE) defined as the composite of all-cause mortality, stroke/transient ischemic attack (TIA), or main access site-related Valve Academic Research Consortium 3 major vascular complications. Outcomes were also stratified according to the severity of PAD using a novel risk score (Hostile score). RESULTS: Among the 1,707 patients included in the registry, 518 (30.3%) underwent TAVR with TFA after percutaneous treatment, 642 (37.6%) with TTA, and 547 (32.0%) with TAA (mostly transaxillary). Compared with TTA, both TFA (adjusted HR: 0.58; 95% CI: 0.45-0.75) and TAA (adjusted HR: 0.60; 95% CI: 0.47-0.78) were associated with lower 30-day rates of MAE, driven by fewer access site-related complications. Composite risks at 1 year were also lower with TFA and TAA compared with TTA. TFA compared with TAA was associated with lower 1-year risk of stroke/TIA (adjusted HR: 0.49; 95% CI: 0.24-0.98), a finding confined to patients with low Hostile scores (Pinteraction = 0.049). CONCLUSIONS: Among patients with PAD undergoing TAVR, both TFA and TAA were associated with lower 30-day and 1-year rates of MAE compared with TTA, but 1-year stroke/TIA rates were higher with TAA compared with TFA.


Assuntos
Ataque Isquêmico Transitório , Doença Arterial Periférica , Acidente Vascular Cerebral , Substituição da Valva Aórtica Transcateter , Humanos , Resultado do Tratamento , Sistema de Registros
19.
Minerva Med ; 114(5): 628-633, 2023 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-35191294

RESUMO

BACKGROUND: Hypercoagulability is often seen in COVID-19 patients and thromboembolic events appear frequent; antithrombotic treatment has been proposed therefore as part of standard treatment for COVID-19. Under these premises, prior-to-infection antithrombotic treatment may have a protective effect with respect to COVID-19 related thromboembolic events. Aim of the present work was to evaluate the impact of prior-to-infection anticoagulant or antiplatelet treatment on COVID-19 outcomes. METHODS: Beneficiaries of the Regional Health Service of the Lombardy region of Italy aged ≥40 years with a COVID-19 diagnosis made between February 21st and July 18th, 2020 were included in the present study. The impact on COVID-19 mortality of pre-existing and chronic therapy with anticoagulant drugs (vitamin-K antagonist or new oral anticoagulants) was evaluated. Analyses were repeated with antiplatelets drugs. RESULTS: Among 79,934 SARS-CoV-2 patients beneficiaries of the Regional Healthcare System of the Lombardy Region who received a diagnosis between February 21st and July 18th, 2020, chronic pre-existing anticoagulant assumption was present in 6.0% and antiplatelets in 12.7%. The overall unadjusted mortality rate was 20.6%, with male sex, age category and comorbidity burden being significantly associated to increased mortality risk. Anticoagulant chronic treatment was not associated with a reduction in mortality. Similar results were observed when repeating the analyses for pre-existing oral antiplatelet treatment. CONCLUSIONS: In a large population-based study evaluating more than 79,000 COVID-19 patients, pre-existing antithrombotic therapy was not associated to a benefit in terms of mortality. Further studies are needed to evaluate the role of antithrombotic therapy as standard treatment among COVID-19 patients.


Assuntos
Anticoagulantes , COVID-19 , Humanos , Masculino , RNA Viral , Fibrinolíticos/uso terapêutico , COVID-19/epidemiologia , Teste para COVID-19 , SARS-CoV-2
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...